The level meters are suited to level measurement of various liquid materials, sewerage waters, mash and paste materials, and suspensions in closed or open vessels, sumps, reservoirs, and open channels. In case the level of bulk solids is measured, the measurement range is reduced. We recommend consulting the use with the manufacturer.
Features
- Universal use, direct mounting into tanks, vessels, containers, sumps, etc.
- Instant view of measured values on OLED or LCD.
- Advanced signal processing with the elimination of false reflections.
- Easy adjustment even without measured material.
- Current or data output – 4 … 20 mA, HART®, RS-485 Modbus/RTU.
- Xi version for usage in explosive areas.
Specification
Measuring range | ULM–70_–02 | 0.15 … 2 m |
ULM–70_–06 | 0.25 … 6 m | |
ULM–70_–10 | 0.4 … 10 m | |
ULM–70_–20 | 0.5 … 20 m | |
Adjustable measuring range (SPAN) | Min. 200 mm | |
Supply voltage | ULM–70_– _ _ | 18 … 36 V DC |
ULM–70Xi–_ _ | 18 … 30 V DC | |
Output | ULM–70_–_ _–_–I | 4 … 20 mA (Limit values 3.9 … 20.5 mA), HART® |
ULM–70_–_ _–_–M | RS-485 with protocol Modbus RTU | |
Current consumption | ULM–70_–_ _-_-I | 4 … 20 mA / Max. 22 mA |
ULM–70_–_ _-_-M | Max. 20 mA | |
Resolution | ULM–70_–02; 06 | < 1 mm |
ULM–70_–10 | < 2 mm | |
ULM–70_–20 | < 2,5 mm | |
Accuracy (within the total range) | 0,15% | |
Temperature error | Max. 0,04% / K | |
Operating frequency | ULM–70_–02 | 120 kHz |
ULM–70_–06 | 75 kHz | |
ULM–70_–10 | 50 kHz | |
ULM–70_–20 | 30 kHz | |
Beamwidth (-3 dB) | ULM–70_–02; 10 | 10° |
ULM–70_–06 | 14° | |
ULM–70_–20 | 12° | |
Ambient temperature range | ULM–70_–02; 06 | -30 … +70°C |
ULM–70_–10; 20 | -30 … +60°C | |
Short-time temperature stress resistance | +90°C / 1 hod. | |
Max. operation overpressure (on transmission surface) | 0,1 MPa | |
Sensitivity 3 stupně | (low – medium – high) | |
Damping | 0 … 99 s | |
Measuring period | 1 … 4 s | |
Rise time | cca. 30 s | |
Additional technical data for Ex proof – Max. internal values | Ui=30V DC; Ii=132mA; Pi=0,99W; Ci=370nF; Li=0,9mH | |
Failure indication (echo loss, level in dead zone 3), internal failure) | Adjustable in modes: 3.75 mA ; 22 mA ; Last measured value | |
Protection class | IP67 | |
Mechanical connection | ULM–70_–02 | Screwing with thread G 1” |
ULM–70_–06 | Screwing with thread G 1½” | |
ULM–70_–10 | Screwing with thread G 2¼” | |
ULM–70_–20 | Aluminium alloy flange | |
Recommended cable | ULM–70_–_ _–_–I | PVC 2 x 0,75 mm2 |
ULM–70_–_ _–_–M | PVC 2 x 2 x 0,25 mm2 (twisted pair, shielded) | |
Maximal resistance of current output load | U = 24 V DC | Rmax = 270 Ω 2) |
U = 22 V DC | Rmax = 180 Ω | |
U = 20 V DC | Rmax = 90 Ω | |
U = 19 V DC | Rmax = 45 Ω | |
Weight | ULM–70_–02 | 0.3 kg |
ULM–70_–06 | 0.4 kg | |
ULM–70_–10 | 0.7 kg | |
ULM–70_–20 | 3.1 kg |