Delta Elektrogas VMM Multiple safety solenoid valve for gas regulating trains

2 minutes, 6 seconds Read

The VMM type valve is a combination of two solenoid valve in an only compact and versatile valve huosing.

The first valve is a fast opening safety solenoid valve. The second valve may be a fast opening or a slow opening solenoid valve to adjust the gas flow, with a first adjustable fast stroke and a second adjustable slow stroke. It is possible connect a third by-pass / pilot valve, which performs by driver stage or to obtain a second fast (slow) stroke or both.

This type of device is suitable for air or gas blocking and releasing controls (with one or two stages operation), required in gas power burners, atmospheric gas boiler, industrial klins and in all gas equipments which use regulating trains.

Baca juga: Elektrogas automatic safety solenoid valves

Function and Application

The VMM type valve is a safety shutting device using auxiliary power supply. The first valve (A) is a fast opening safety solenoid valve.When it is de-energized, the spring pushes on the seal disc, keeping the gas passage closed. Now, the inlet chamber is under the gas line pressure, and it forces on the disc too, improving the seal.

Delta Elektrogas-VMM application and function

If the power supply is shut off, the valve rapidly closes, interrupting the gas flow. Equally, the second valve (B) may be a fast opening or a slow opening solenoid valve to adjust the gas flow, with a first adjustable fast stroke and a second adjustable slow stroke. It is possible to connect a third by-pass valve (C), which works as low fire stage or to obtain a second fast (slow) stroke or both.

Specification

ConnectionsGas threaded ISO 7-1 from Rp3/4 to Rp2 or ANSI-ASME B1.20 from 3/4″ NPT to 2″NPT
Flanged PN16 – ISO 7005 from DN40 to DN80 or ANSI-ASA-ASME B16.5 class 150 from 2″ to 3″
By-pass sizeDN15 or DN25
Voltage rating230 VAC 50/60 Hz
120 VAC 50/60 Hz
110 VAC 50/60 Hz
24 VAC/DC
Voltage tolerance-15% / +10%
Power consumption70W for 3/4″ – 1″
90W (working) for 1″1/4-3″
by-pass 1/2″ 25W
by-pass 1″ 35W
Ambient temperature
Media temperature
-15 C / +60C (+5F to +140F)
Max. operating pressure200 mbar  (3 psig)
500 mbar (5 psig)
Body test pressure1 bar (15 psig)
Flow capacitysee charts
Closing time< 1 second
Opening timeAdjustable
Pressure portsG1/4 (add. G1/8 into flange models)
Gas trainers600 m (0.02 in), metal mesh
EnclosureIP54 (NEMA 3)
Optional IP65 with cable (NEMA 4)
Cable glandM20x1,5 for terminal box
PG 9 for ISO plug
Wires cros-section2,5 mm2 max. (AWG 12) for terminal board
1,5 mm2 max (AWG 14) for ISO plug
Electrical safetyClass I (EN 60335-1)
Coil winding insulationClass H (200C, 392F)
Coil thermal resistanceClass F (155C, 311F)

Data Sheet Delta Elektrogas-VMM

Visit Wmablog for more info and price or

Buat Penawaran

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *