Hengstler Tico 772/773/774 Time counter

4 minutes, 43 seconds Read
Application Input/Output (Timer)Output: preset 0-out
input: additional Run
Stop
Reset
Set
Keylock
Teach in
Accuracy of the TimerTimebase. ± 30 ppm
Start / Stop time point: 16 µs / 16 ms (unattenuated / attenuated)
resolution: 100 µs = 100 ppm
Overall Tolerance (Timer)= display resolution + tolerance time base = 130 ppm
Resolution1, 0.1, 0.01, 0.001, 0.0001

Environment and security

IP Protection ClassIP 65
Operating Temperature [°C]0 …… + 50 °C (+ 32 … 122 °F) EN 60 068-2-1/2
Storage Temperature [°C]– 20 … + 65 °C (- 4 … + 149 °F) EN 60 068-2-1/2
Degree of ProtectionIP 65 front, EN 60529
IP 20 connections
Cable LengthAn additional protective circuit is required when using cables longer than 30 m
which are connected to a DC power supply at TTL input levels
General DesignEN 61 010-1 / IEC 61010-1
EMC – Interference immunityEN 61326-1 Industrial**
EMV-EmissionEN 61326-1 Class B*
ApprovalsUL
CSA File-Nr. E 338588
Vibration Resistance10 m/s² (33 ft/s²) (10 . 150 Hz), EN 60 068-2-6
Shock Resistance100 m/s2 (328 ft/s2) (18 ms) acc.IEC 068-2-27
Protection ClassII, EN 61010-1 / IEC 61010-1
Contamination LevelV 2
EN 50178
Climate40°C (104 °F)/ 93% RH class 4K4H
EN 60 068-2-78
25 – 50°C (122 °C) / 93% RH
cyclic
EN 60 068-2-38
elevations up to 2000 m (6561 ft)
Resistance to Chemicalsfront film acc. DIN 42 115-2
RoHScompliant

Mechanical

Size [mm]48x48x118
Mounting OptionsClamping frame
Mountingwith clamping frame
Resetmanual reset using keypad
external reset static or dynamic
pulse duration min. 5 ms
automatic reset after preset 2 has been reached
no loss of pulse at the maximum counting frequency due to automatic resetting. programmable using application input and power-up reset
Weight [g]approx. 200 g (3.2 oz)
Dimensions [mm]48 mm x 48 mm x 118 mm (1.9×1.9×4.6 in), installation depth 110 mm (4.4 in), DIN 43 700
Panel Thickness [mm]max. 11 mm