Water leaks Detection
Ultrasonic water meters FLOMIC FL5024 and FL5044

Water leaks Detection

2 minutes, 29 seconds Read

Water Leaks Detection FLOMIC FL5034 and FL5054 ultrasonic flow meters are intended for operational and invoicing measurements of instantaneous flow rate, pressure, and consumption in water piping in observance of standard EN 14154 in waterworks, water distribution systems, and other industrial applications. The features of the FLOMIC flow meters make them suitable for water leak detection and tracking and monitoring of the general condition of water-supply networks.

Ultrasonic flow meter FL 50X4 design

These flow meters are of a compact design with the IP 68 protection class. They are characterized by high measurement accuracy and long-term stability over a wide range of measured values. The meters do not need any external power supply, do not include any moving parts and, have significantly lower hydraulic losses.

The measurement method utilized by these meters is a single-beam (FL5034) or dual-beam (FL5054) transit-time pulse method based on evaluation of the time needed for an ultrasonic signal to cross the distance between two measuring transductors. In the standard version, the meter measures instantaneous flow rate (in m3/hour) and the total volume of water passed through the meter (in m3) in the given flow direction.

The measured data are converted into passive pulse output signals. The meter output signals can be connected via data transfer systems to remote computer control stations. Flowmeter electronics also includes data storage with various possibility to connect (GSM module, RS232, optical data probe).

This feature can be useful for distance measuring points without electricity. Flow meters FLOMIC FL 50X4 can effectively save customers’ costs everywhere, where it needs to measure water and is not possible or is expensive to connect to an energy power grid.

Technical Parameters
usage measurement of the total volume of the water passed through and instantaneous flow rate and pressure
the principle of the measurement transit-time
type – one beam (1B – FL5034) or dual beam  (2B – FL5054)
– compact version
the range of dimensions DN32 to DN300
the temperature of the measured fluid to 50°C
pressure up to 4.0 MPa
flow sampling period 1 sec
electrical outputs pulse and current
interface optical probe, RS 232, GSM module
data storage data archive
power source Li-battery 3.6V, 16Ah, lifetime 6 to 8 years
protection class IP68