The Fluke 922 makes airflow measurements easy by combining pressure, airflow, and velocity into a single, rugged meter. Compatible with most pitot tubes, the Fluke 922 allows technicians to conveniently enter their duct shape and dimensions for maximum measurement accuracy.
The Fluke 922 Airflow Meter helps you:
- Monitor air pressure across key HVAC components
- Ensure proper airflow balance
- Promote good indoor air quality
- Maintain a comfortable environment
Use the Fluke 922 to:
- Measure pressure drops across filters and coils
- Match ventilation to occupant loads
- Monitor indoor vs. outdoor pressure relationships and manage the building envelope
- Perform duct traversals for accurate airflow readings
Features:
- Powerful meter provides differential and static pressure, air velocity and flow readings
- Rugged design built for field use
- Easy to use without sacrificing performance
- User-defined duct shape and size for maximum airflow accuracy
- Convenient colored hoses help you properly diagnose pressure readings
- Bright, backlit display for clear viewing in all environments
- Min/Max/Average/Hold functions for easy data analysis
- Auto power off saves battery life
Specification:
- Operating
Feature | Range | Resolution | Accuracy |
Air Pressure | ± 4000 Pascals ± 16 in H2O ± 400 mm H2O ± 40 mbar ± 0.6 PSI | 1 Pascal 0.001 in H2O 0.1 mm H2O 0.01 mbar 0.0001 PSI | ± 1 % + 1 Pascal ± 1 % + 0.01 in H2O ± 1 % + 0.1 mm H2O ± 1 % + 0.01 mbar ± 1 % + 0.0001 PSI |
Air Velocity | 250 to 16,000 fpm 1 to 80 m/s | 1 fpm 0.001 m/s | ± 2.5 % of reading at 2000 fpm (10.00 m/s) |
Air Flow (Volume) | 0 to 99,999 cfm 0 to 99,999 m3/hr 0 to 99,999 l/s | 1 cfm 1 m3/hr 1 l/s | Accuracy is a function of velocity and duct size |
Temperature | 0 °C to 50 °C 32 °F to 122 °F | 0.1 °C 0.1 °F | ± 1 % + 2 °C ± 1 % + 4 °F |
- General Specifications
Operating Temperature | 0 °C to +50 °C (+32 °F to +122 °F) |
Storage Temperature | -40 °C to +60 °C (-40 °F to +140 °F) |
Operating Relative Humidity | 0 % to 90 %, non-condensing |
IP Rating | IP40 |
Operating Altitude | 2000 m |
Storage Altitude | 12000 m |
EMI, RFI, EMC | Meets requirements for EN61326-1 |
Vibration | MIL-PREF-28800F, Class 3 |
Max Pressure at Each Port | 10 PSI |
Data Storage | 99 readings |
Power | Four AA batteries |
Typical Battery Life | 375 hours without backlight, 80 hours with backlight |
Model Completeness
- Fluke-922 Airflow Meter: Fluke 922 Airflow Meter, Two Rubber Hoses, Wrist Strap, Four AA Batteries 1.5 V Alkaline, Users Manual and Soft Carrying Case
- Fluke-922/Kit Airflow Meter: Fluke 922 Airflow Meter, 12 in. pitot tube, ToolPakTM, Two Rubber Hoses, Wrist Strap, Four AA Batteries 1.5 V Alkaline, Users Manual and Hard Carrying Case
- PT12: Pitot Tube, 12 in
Resource: https://www.fluke.com/