Features
Nominal Flow (Qₙₒₘ)* | 2500 kg/min (5512 lb/min) |
Maximum Flow (Qₘₐₓ)* | 3000 kg/min (6614 lb/min) |
Typical Minimum Flow (Qₘᵢₙ)* | 30 kg/min (66 lb/min) |
Operating Temperature | Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F). For integral transmitter versions please refer to the transmitter datasheet |
Ambient Temperature | -50 °C to +80 °C (-60 °F to +180 °F) (standard) |
Pressure Ratings | Up to 490 bar / 7107 psi – dependent upon material |
Electrical Connection Sensor w/o Integral Transmitter | M20 x 1.5 standard cable entry for JM, SM terminal box versions |
Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM) | |
Max. cable length to remote RHE transmitter 100 m / 328 ft | |
Sensor Enclosure Materials | Stainless steel 304 (standard), SS 316 (optional) |
Coated aluminum terminal box, SS 316 terminal box (optional) | |
Enclosure Type | Protection class IP65, NEMA 4 (standard); IP66 / NEMA 4X (optional) |
Wetted Materials | 1.4571 (SS 316Ti), 1.4410 (SuperDuplex) – standard |
2.4602 (Alloy C22) – consult Factory | |
Additional/customer specific materials available upon request | |
Process Connections | Nearly any – the Rheonik AnyPipeFit Commitment. Consult the factory for types/sizes not listed in this data sheet on the Mechanical Construction pages |
Pressure Rating Compliance | Europe – PED: Module A2, Module B3.1+C2 |
Canada – CRN: Canadian Registration Number | |
Certifications and Approvals | ATEX / IECEx Approvals for Zone 0, 1 (details see page 10) |
North American Approvals Class I, Div. 1, 2, Gr. A, B, C, D, Zone 0, 1, 2 | |
MID custody transfer approval (OIML R117) | |
American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels | |
Testing and Inspection | All sensors are hydro tested, calibrated, and supplied with a traceable calibration certificate. Customized calibration and testing services are available |
Project Documentation and QA, Services | Rheonik offers a full set of services for large and complex engineering projects. |
Typical services offered are but are not limited to:•Certificates of origin and conformity, mill certificates•Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance etc.•Painting to project specification•Start up and commissioning services on/offshore | |
Options | Enclosure heating for high temperature applications |
Cleaning for oxygen service, … | |
For more consult the factory |