The battery-powered FLOMIC FL5024 and FLOMIC FL5044 ultrasonic water meters are intended for operational and invoicing measurements of instantaneous flow rate, pressure and consumption in water piping in observance of standard EN 14154 in waterworks, water distribution systems and other industrial applications.
These water meters are of a compact design with the IP 68 protection class. They are characterized by high measurement accuracy and long-term stability over a wide range of measured values. The meters do not need any external power supply, do not include any moving parts and, have significantly lower hydraulic losses.
The technical parameters and other features of the FLOMIC water meters make them suitable not only for water consumption measurements but also for water-leak tracking and monitoring of the general condition of water-supply networks, where the meter output signals can be connected via data transfer systems to remote computer control stations.
The measurement method utilized by these meters is a single-beam (FL5024) or dual-beam (FL5044) transit-time pulse method based on the evaluation of the time needed for an ultrasonic signal to cross the distance between two measuring transducers. In the standard version, the meter measures instantaneous flow rate (in m3/hour) and the total volume of water passed through the meter (in m3) in the given flow direction. The measured data are converted into passive pulse output signals.
Optional Meter Accesories:
- The bi-directional flow rate and volume measurements with the visual and electronic indication of the actual flow rate direction.
- Measurement and display of instantaneous water pressure values within the range of 1 to 16 bar.
- Using a passive current output signal 4 to 20 mA, monitoring the instantaneous flow rate or flow pressure values.
- Measured data storage with a user-selectable sampling period of 1 minute to 1 year.
Actual and stored data reading via the USB or RS 232 interface.
- Connection to a remote data transfer system by means of a GSM module.
- Use of alternative measurement units (Gal/min, or liter/sec).
- Application of the meter within drinking-water supply systems.
- Power supply via the 4 to 20 mA current line.
Technical Parameters | |
usage | measurement of the total volume of the water passed through and instantaneous flow rate and pressure |
the principle of the measurement | transit-time |
type | – one beam (1B – FL5024) or dual beam (2B – FL5044) |
– compact version | |
the range of dimension | DN32 to DN200 |
a temperature of a measured fluid | to 50°C |
pressure | up to 1.6 MPa |
flow sampling period | 1 sec |
electrical outputs | pulse and current |
interface | an optical probe, RS 232, GSM module |
data storage | data archive |
power source | Li-battery 3.6V, 16Ah, lifetime 6 to 8 years |
protection class | IP68 |
Read Another Article :
- Flowma Flowmasonic WUF 620 J Portable Ultrasonic Flow Meter
- Ultrasonic Flow Meter : Prinsip Kerja, Jenis, dan Kelebihannya
- Flowma Flowmasonic WUF 620 CF Clamp On Ultrasonic Flow Meter
- Cara Instalasi Flow Meter Ultrasonic Clamp-on Flowmasonic WUF 500
- Flow meter Air Jenis Ultrasonic clamp on Flowmasonic WUF 500
- Water flow sensor jenis clamp on ultrasonic flow meter
- Flowma Flowmasonic WUF 620 J Portable Ultrasonic Flow Meter
- Flow meter ultrasonic clamp on untuk pipa HDPE
- Flow Meter Ultrasonic Jenis Clamp On Untuk Pipa PVC
- Flow Meter Ultrasonic Clamp on untuk Proses Destilasi Air Laut
- Flow Meter Ultrasonic Portable untuk Mengecek Sistem Pendingin Mesin
- Jarak panjang Pipa pemasangan transducer ultrasonic
- Flow meter ultrasonic yang digunakan untuk sistem pemadam kebakaran