The Sage 300 thermal mass flow meter is an economical alternative to Sage Prime® while offering comparable performance. The meter measures gas mass flow and has the same accuracy, repeatability, low-end sensitivity, response time, turn down and resolution as the Prime without some premium features.
If the user needs to verify that the meter is in calibration, while still in the field and in the pipe, use the Sage Prime, which includes the award-winning Sage In-Situ Calibration Verification. Likewise, if a high-contrast graphical display is desired, the Prime will better serve your needs. The 300 is manufactured to accommodate our customers in the United States and Canada.
Features
- Available in 24 VDC or 115/230 VAC
- Isolated 4-20 mA signal and pulsed output of a total flow
- Available with integral or remote electronics
- For remote models, lead length compensation permits cable lengths up to 1000 feet
- NEMA 4 and explosion-proof junction box
- For use with a ½” insertion probe in 1″ and larger pipe or in the in-line flow, body sizes 1/4″ to 4″
- Available in blind configuration or display with window providing flow rate, total flow and gas temperature.
Benefits
- Measures mass flow.
- Sage meters have the lowest rate of energy loss with a power dissipation of 2.5 watts, making them the most efficient thermal mass flow meter.
- All units come calibrated from the Sage NIST traceable calibration facility and are preconfigured with the specified process and installation parameters for the application.
- The meter has a two-compartment compact housing with a separate wiring section containing large, easy to access terminals to simplify field installation.
Applications
- Natural gas flow to burners
- Compressed air flow measurement
- Combustion air
Specifications
Performance
- Accuracy: +/– 1% of reading plus 0.5% of full scale
- Repeatability: 0.2% of reading
- Low-End Sensitivity: 5 SFPM (1 SCFM in 6″ pipe)
- Response Time: 1 second time constant
- Turndown: 100:1
- Resolution: 1000:1
Electronics
- Power: 24 +/-10% VDC or 90 – 265 VAC
- Output: 4-20 mA
- Pulse: 100 mA maximum
- Isolated: External powered 4-20 and pulse
- Modbus: RS 485 RTU optional
- Ratings: Class I, Division 2, NEMA 4, CE
- Ambient Temperature: –40 to 150° F (–40 to 65° C)
Sensor
- Type: Insertion probe (1/2″ diameter), flow body (1/4″ to 4″)
- Materials: 316 stainless steel and Hastelloy C
- Process Temperature Range: –40 to 450°F (–40 to 230° C)
- Process Pressure: Max 500 PSIG
For more information, visit wma.co.id
Other Articles
- Small Size Coriolis Mass Flow Sensor RHM 04 Low Flow Mass Flow Meter flow rate
- Medium Size Coriolis Mass Flow Sensor RHM 20 Mass Flow Meter flow rate
- Large Size Coriolis Mass Flow Senso RHM 100 Coriolis Flow Mass Meter flow rate
- Flow Meter Open Channel Untuk PLTU
- Instalasi Flow meter ultrasonic clamp on untuk air dingin mesin chiller
- Prosedur Instalasi Flow Meter Electromagnetic
- Meteran air Jenis flow meter Ultrasonic
- Flow meter ultrasonic clamp on untuk pipa HDPE
- Penggunaan Flowmeter Ultrasonic Pada Pengolahan air limbah
Contact us : sales@wmablog.com or visit to our E-Commerce
Source: inaparts.com